- Metal box with grounding.
- Central illuminated ON-OFF switch.
- Central safety 6A.
- Separate fuses for burner, circulator, electric valves and thermostats.
- Function indicators for each partition.
- Diode command receptors 1N4007 (DS, D, Δ / 2K, Δ / 3Κ).
- Relay command receptors 10A (R, K).
- Output relay 10A for burner and circulator (R, DS, D).
- Separate output relay 10A for burner and circulators (D / 2K, Δ / 3K, K).
- Operating voltage 230 V AC.
- Contact magnet relay 10A.
- Inlet and outlet connection terminal type with 2.5 mm gap.
Autonomy Tables
03 General Characteristics
- Metal box with grounding.
- Autonomy tables with R code are relay panels for each compartment (solenoid) and a central relay for burner and circulator. In these tables the last electromagnetic valve remains open or not.
- DS autonomy panels are dashboards for each compartment (electrovalve) and a central relay for a burner and a circulator. In these tables the last electrovalve is not open.
- D-code autonomous panels are dowelboards for each compartment (solenoid) and a central relay for a burner and a circulator. In these tables the last electromagnetic valve remains open or not.
- Autonomy tables with D / 2K code are tables serving two different pump networks. They have a passage for each compartment (solenoid) and separate relay for burner and circulators. In these tables the last electromagnets with the respective circulator remain open or not.
- Autonomy tables with code Δ / 3K are tables serving three different circulation pump networks. They have a passage for each compartment (solenoid) and separate relay for burner and circulators. In these tables the last electromagnets with the respective circulator remain open or not.
- K-type autonomous tables are tables that serve autonomous installations from two to twelve circulators with non-return valves. They have a relay for each compartment (space thermostat) and separate relays for burner and circulators. In these tables the last circulator remains open.