V-FP1 Hydro Digital Thermostatic Fire Controller

05 General characteristics

  • DIFFERENTIAL DRIVE UNIT IN LOCKED DINRAIL 6 RAIL BOX IN WALL-MOUNTED IP40 ENCLOSURE TO PROTECT AGAINST POWER SURGES, DUSTS, HUMIDITY.
  • 2 X 8-LINE LCD 2-WAY LCD ON A GREEN BACKGROUND WITH CONTINUOUS DISPLAY THE BASIC FUNCTIONS (CONFIGURATION THAT WE HAVE SELECTED, STATUS ASSIST SOURCE, SENSOR TEMPERATURES AND RELAY STATUS).
  • IT SUPPORTS AND CONTROLS 8 DIFFERENT SYSTEMS (CONFIGURATIONS) USING HYDROTHERMAL FIREPLACES
  • TEMPERATURE CONTROL OF 1 TO 4 SENSORS DEPENDING ON CONFIGURATION.
  • DIFFERENTIAL CONTROL BETWEEN THE BUFFER FIREPLACE WITH SIMULTANEOUS DIFFERENTIAL CONTROL BETWEEN OPEN AND CLOSED RADIATOR HYDRAULIC CIRCUITS.
  • CHECK FROM 1 TO 3 CIRCULATORS.
  • CONTROL OF BYPASS VALVES OR TRIPODS.
  • CONTROL OF HEATING RADIATOR HYDRAULIC CIRCUITS.
  • SENSOR FAULT DETECTION SYSTEM.
  • WATER TANK PROTECTION SYSTEM.
  • HYDRAULIC PIPING SYSTEM PROTECTION FROM OVERHEATING.
  • COMPLETE CONFIGURATION OF FACTORY SETTINGS FROM EASY TO USE AND UNDERSTANDABLE MENU.
  • POWER SUPPLY 230 VAC.
  • THREE DRY CONTACTS RELAY 6A / 230 VAC – 30 VDC.
  • WALL MOUNTING.
  • SENSORS OF THE DEVICE ARE V-KTY50 OR V-KTY300.

06 Downloads